In Uptick, there is the ability to create an Annual Fire Safety Statement (AFSS) each year on the NSW government template. Each time this template has amendments, we provide a new template version for you to transfer across to when required.

Before you can get started

Make sure you have Annual Certification NSW (AFSS - Sep 2022) document template added to your server. To learn more, review Document Templates support article.

  1. Enable the ESMs module in extensions (see support for assistance).

  2. If using Signoffs, enable this module (this can only be used with ESMs).

  3. Edit any asset types/ESM's you'd like to display in Section 5.
    Edit > Applicable to AFSS Section 5 > YES (if the field is not available you can add via the custom field process)

  4. Ensure you have the DP/DN field on the property - if not available you can add it via the custom field process

  5. Setup all users with their relevant APFS number if applicable via:
    Users > View > Update (Preferences) > Fill in FPAA FSA No. If you do not have this option currently displayed, please contact our support team.

  6. Set up all users with their signatures.

Generating a task

  1. Add the applicable ESMs to the properties required.

  2. Add an appropriate routine to generate a task when the AFSS is required. This may be a certification routine or you may choose to name it AFSS. You can also add an ESM audit routine if you need to attend before the servicing starts.

  3. Generate the task when required through the normal process.

  4. Perform all associated items you'd like to display on the AFSS from the tasks work tab.

  5. Preview AFSS.

  6. Dispatch AFSS report to the client.

Where the AFSS populates from

Section 1: Type of statement

Template Field

Uptick Field/Description

This is (mark applicable box):
(tick box)

Our system will automatically tick AFSS, not supplementary. If you need supplementary AFSS's, please contact support to obtain this template.

Section 2: Description of the building or part of the building

Template Field

Uptick Field/Description

This statement applies to (tick box)

Property > Building attributes > Building Part

Note: If no text in this field it assumes and ticks the whole building.

If specified, it will tick part of the building.

Address (Street No., Street Name, Suburb and Postcode)

Property Display Address

Lot No. (if known)

Property > (Location) Update > Manually set address fields > Land/Lot number

DP/SP (if known)

For DP (Development Plan) DP/DN

For SP (Strata Plan/OCSP) OCSP number

Note: If DP/DN field is not available you can add it via the custom field process

Property Name (if applicable)

Property > (Location) Update > Manually set address fields > Building or Business Name

Or;

Property > Property Name

Provide a brief description of the building or part (building use, number of storeys, construction type etc)

PART: Property > Building attributes > Building Part

If no text in this field it displays the wording Whole Building.

If specified, displays text

BUILDING USE: Property > Building attributes > Building Classes,

or;

Property > Building attributes > Building use

or;

Property > Building attributes > Building class

SIZE: = Property > Building attributes > Additional building attributes> Building size & Building size (sqm)

CONSTRUCTION TYPE: Property > Building attributes > Additional building attributes > Construction class

STOREYS ABOVE GROUND: = Property > Building attributes > additional building attributes> Stories above ground

STOREYS BELOW GROUND: = Property > Building attributes > additional building attributes> Stories above below.

Section 3: Name and address of the owner(s) of the building or part of the building

Template Field

Uptick Field/Description

Full Name (Given Name/s and Family Name)

For OCSP: = Property > Set Strata details > OCSP NUMBER

If the property has an OCSP Number specified e.g. OC12345:

The Name will be listed as "Owners corporation: OC12345"

For Owner: =Will display the Name of the active property contacts where the role is Owner

Address (Street No., Street Name, Suburb and Postcode)

For OCSP: Property display address

For Owner: Address of the active property contacts where the role is Owner

Section 4: Fire safety measures

Template Field

Uptick Field/Description

Fire safety measure

ESM: ESM’s listed on the task’s work tab under performed

Note: you can override the label by updating the specific ESM or though updating the label of the ESM type in the Control Panel (to be applied to all ESMs on your server).

Note: ESMs must be listed on the performed work tab before they will populate.

Minimum standard of performance

Standard of Performance: listed against each ESM.

Date(s) assessed

Last service date

APFS*

User who serviced measures

To set/view this number, see step 4 at the beginning of this article.

Section 5: Inspection of fire exits and paths of travel to fire exits (Part 15)

Template Field

Uptick Field/Description

Part of the building inspected

Paths of travel ESM

Note: All paths of travel ESM types are tagged to populate here (usually done in setup).

The ESM must have a location, otherwise, the words WHOLE BUILDING will appear after the label text in this section, even if the AFSS is for part of the building.

Date(s) assessed

Last service date

APFS*

User who serviced measures

To set/view this number, see step 4 at the beginning of this article.

Section 6: Name and contact details of each accredited practitioner (fire safety) (APFS)*

Template Field

Uptick Field/Description

Full name (Given Name/s and Family Name)

Address

Phone

APFS*

Signature

Pulls through last serviced users or contractors details;

Full name, phone, FPAA FSA No (APFS) and their stored user signature.

Sections 7, 8 and 9

Sections 7,8 and 9 have been left blank to adhere to the below AFSS guidelines:

The person who makes the required declaration by completing section 8 or section 9 of the form must not be an APFS who was involved in the assessment of any of the fire safety measures, or inspection of the building for the purposes of the statement, or their employer/employee or direct associate. This is to ensure that building owners, who are ultimately responsible, remain engaged in the fire safety statement process.